Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
1.
Front Bioeng Biotechnol ; 12: 1354241, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38288261

RESUMO

Objective: The present study aimed to assess the bond strength and durability of six bonding agents concerning their application to metal or ceramic brackets and zirconia. Materials and Methods: Six resin cement bonding agents (XT, XTS, RSBU, RGBU, SBPM, and GMP) were chosen for this investigation. Specimens were either stored in distilled water at 37°C for 24 h or subjected to 5,000 thermocycles before conducting a Shear Bond Strength (SBS) test. Statistical analysis of the SBS data was performed using three-way ANOVA and Games-Howell tests (α = 0.05). The Adhesive Remnant Index was examined, and the debonding surface details on brackets and zirconia were observed. Results: For metal brackets, all groups demonstrated clinically acceptable bond strength, irrespective of storage conditions, except for the XT group. Regarding ceramic brackets, all groups displayed acceptable bond strength after 24 h of water storage. However, following thermocycling, a significant decrease in SBS was noted across all groups (p < 0.05), with SBPM exhibiting a higher bond strength. Three-way ANOVA analysis indicated that SBS values were notably influenced by each factor, and an interaction among the three independent variables was observed (p = 0.000). Conclusion: The reliable bond strength between ceramic brackets and zirconia was significantly lower after thermocycling compared to that of metal brackets and zirconia. SBPM exhibited consistent and robust bond strength between ceramic/metal brackets and zirconia across various storage conditions. Furthermore, the HEMA-free adhesive demonstrated a potentially more consistent bonding performance compared to the HEMA-containing adhesive employed in this study.

2.
Antibiotics (Basel) ; 12(9)2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37760711

RESUMO

Chlorhexidine is the most commonly used anti-infective drug in dentistry. To treat infected void areas, a drug-loaded material that swells to fill the void and releases the drug slowly is needed. This study investigated the encapsulation and release of chlorhexidine from cellulose acetate nanofibers for use as an antibacterial treatment for dental bacterial infections by oral bacteria Streptococcus mutans and Enterococcus faecalis. This study used a commercial electrospinning machine to finely control the manufacture of thin, flexible, chlorhexidine-loaded cellulose acetate nanofiber mats with very-small-diameter fibers (measured using SEM). Water absorption was measured gravimetrically, drug release was analyzed by absorbance at 254 nm, and antibiotic effects were measured by halo analysis in agar. Slow electrospinning at lower voltage (14 kV), short target distance (14 cm), slow traverse and rotation, and syringe injection speeds with controlled humidity and temperature allowed for the manufacture of strong, thin films with evenly cross-meshed, uniform low-diameter nanofibers (640 nm) that were flexible and absorbed over 600% in water. Chlorhexidine was encapsulated efficiently and released in a controlled manner. All formulations killed both bacteria and may be used to fill infected voids by swelling for intimate contact with surfaces and hold the drug in the swollen matrix for effective bacterial killing in dental settings.

3.
BMC Med Inform Decis Mak ; 23(1): 12, 2023 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-36658526

RESUMO

BACKGROUND: Intensive Care Unit (ICU) readmissions represent both a health risk for patients,with increased mortality rates and overall health deterioration, and a financial burden for healthcare facilities. As healthcare became more data-driven with the introduction of Electronic Health Records (EHR), machine learning methods have been applied to predict ICU readmission risk. However, these methods disregard the meaning and relationships of data objects and work blindly over clinical data without taking into account scientific knowledge and context. Ontologies and Knowledge Graphs can help bridge this gap between data and scientific context, as they are computational artefacts that represent the entities of a domain and their relationships to each other in a formalized way. METHODS AND RESULTS: We have developed an approach that enriches EHR data with semantic annotations to ontologies to build a Knowledge Graph. A patient's ICU stay is represented by Knowledge Graph embeddings in a contextualized manner, which are used by machine learning models to predict 30-days ICU readmissions. This approach is based on several contributions: (1) an enrichment of the MIMIC-III dataset with patient-oriented annotations to various biomedical ontologies; (2) a Knowledge Graph that defines patient data with biomedical ontologies; (3) a predictive model of ICU readmission risk that uses Knowledge Graph embeddings; (4) a variant of the predictive model that targets different time points during an ICU stay. Our predictive approaches outperformed both a baseline and state-of-the-art works achieving a mean Area Under the Receiver Operating Characteristic Curve of 0.827 and an Area Under the Precision-Recall Curve of 0.691. The application of this novel approach to help clinicians decide whether a patient can be discharged has the potential to prevent the readmission of [Formula: see text] of Intensive Care Unit patients, without unnecessarily prolonging the stay of those who would not require it. CONCLUSION: The coupling of semantic annotation and Knowledge Graph embeddings affords two clear advantages: they consider scientific context and they are able to build representations of EHR information of different types in a common format. This work demonstrates the potential for impact that integrating ontologies and Knowledge Graphs into clinical machine learning applications can have.


Assuntos
Ontologias Biológicas , Readmissão do Paciente , Humanos , Reconhecimento Automatizado de Padrão , Aprendizado de Máquina , Unidades de Terapia Intensiva
4.
Dent Mater ; 38(12): 1855-1865, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36202660

RESUMO

OBJECTIVES: In this paper we propose embedding natural fillers, such as pristine and functionalized chitin nanocrystals, into resin adhesives to produce photopolymerizable dental filled adhesives with enhanced biocompatibility, hydrophobicity, mechanical resistance, and anti-bacterial properties. METHODS: Chitin nanocrystals (ChNC) were functionalized with decanoyl chloride and methacrylic anhydride to produce ChNC-C10 and ChNC-MA, respectively. These hydrophobically functionalized chitin nanocrystals were incorporated into a resin adhesive at concentrations of 0.5-3.0 wt% to assess the materials' physical and mechanical properties through Fourier-transform infrared (FTIR) spectroscopy, solid-state NMR spectroscopy, X-ray diffraction (XRD), elemental analysis, scanning electron microscopy (SEM), thermogravimetric analysis (TGA), flexural strength, microhardness, and water sorption tests. RESULTS: The analytical techniques confirmed the successful preparation of chitin nanocrystals from commercial chitin powder derived from shrimp shells and the efficient hydrophobization of their surface. Electron microscope images indicated that the increased hydrophobicity of ChNC-C10 promotes the formation of layered structures throughout the resin adhesive, while ChNC-MA tends to form aggregates in the matrix. Adhesives filled with ChNC-C10 enhanced their flexural strength, microhardness, and thermal stability and decreased their water sorption and degree of conversion. Adhesives filled with ChNC-MA resulted in improvements in microhardness, in water sorption and degree of conversion, although they did not exhibit augmentation of their flexural strength and thermal stability. SIGNIFICANCE: In light of the improved physical and mechanical properties with respect to the control, resin adhesives filled with anti-bacterial chitin nanocrystals are promising new materials for dental applications, especially those filled with low/moderate amounts of ChNC-C10.


Assuntos
Cimentos Dentários , Nanopartículas , Cimentos Dentários/química , Quitina , Teste de Materiais , Interações Hidrofóbicas e Hidrofílicas , Nanopartículas/química , Resinas Sintéticas/química , Água/química , Propriedades de Superfície , Cimentos de Resina/química , Resinas Compostas/química
5.
Dent Mater ; 38(6): 946-959, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35300870

RESUMO

OBJECTIVES: The manufacturing of polymethylmethacrylate(PMMA) microspheres loaded with doxycycline(DOX) and/or silver sulfate(Ag2SO4) to be incorporated into glass ionomer cement(GIC). METHODS: PMMA microspheres were manufactured with Ag2SO4(1-5%) and/or DOX(5-15%). Particle size, encapsulation efficiency and drug release were measured by light microscope, ICP, and HPLC. Microspheres were added to a dental GIC(20%w/w). Drug release and DTS were investigated. Minimum inhibitory concentration and antibacterial effects of PMMA microspheres into GIC materials were tested. RESULTS: The median diameter of 50 µm was obtained for microspheres. DOX was encapsulated at an efficiency of 8.3% using a theoretical loading of 15%DOX + 5%Ag2SO4. The Ag2SO4 encapsulation efficiency was 0.63% using a theoretical loading of 5%AgSO4. All groups showed burst release within the first day and continued released up to 15 days, with 60-83% of DOX and approximately 30% of silver. For GIC, approximately 15% of DOX and 0.18% of silver were released in a 7-day period. Microbiological results showed an antimicrobial effect against S. mutans when the lead formulation of microspheres was added. The DTS was reduced by the inclusion of microspheres. SIGNIFICANCE: PMMA microspheres containing DOX and Ag2SO4 offer a sustained antimicrobial activity for dental applications and promising potential for the biomedical field.


Assuntos
Doxiciclina , Prata , Antibacterianos/farmacologia , Doxiciclina/farmacologia , Cimentos de Ionômeros de Vidro/farmacologia , Teste de Materiais , Microesferas , Polimetil Metacrilato/farmacologia , Prata/farmacologia , Streptococcus mutans
6.
Saudi Dent J ; 34(2): 142-149, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35241904

RESUMO

To study the accuracy and precision of estimating the prevalence, extent and associated risks of untreated periodontitis using partial-mouth recording protocols (PRPs) Methods: A purposive sample of 431 individuals who had never been treated for periodontal disease was recruited from screening clinics at the King Saud bin Abdul-Aziz University for Health Sciences. Data were collected using questionnaires and clinical examinations. The prevalence, extent and risk associations of periodontitis were evaluated. Three PRPs were compared to full-mouth recordings (FRPs) in terms of the sensitivity, specificity, predictive values, and absolute bias. Results: The prevalence of periodontitis was estimated with the highest accuracy and precision by examinations of the full mouth at the mesiobuccal and distolingual sites (FM)MB-DL, followed by random half-mouth (RHM) recordings. The extent of periodontitis was estimated with high precision using all the PRPs, and the absolute bias ranged from -0.6 to -2.3. The absolute bias indicated by OR for risk associations was small for the three PRPs and ranged from -0.8 to 0.8. Conclusion: (FM)MB-DL and RHM were the PRPs with moderate to high levels of accuracy and precision for estimating the prevalence and risk associations of periodontitis. The extent of periodontitis was estimated with high precision using all three PRPs. The results of this study showed that the magnitude and direction of bias were associated with the severity of periodontitis, the selected PRPs and the magnitude of the risk associations.

7.
Clin Exp Dent Res ; 8(1): 380-394, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35015383

RESUMO

OBJECTIVES: to examine the prevalence, extent, and risk associations of untreated periodontitis. MATERIALS AND METHODS: A purposive sample of subjects who were never treated for periodontal conditions was clinically examined after collecting information about their sociodemographic characteristics, medical conditions, oral health behaviors, perceived stress, and perceived social support. RESULTS: A total of 431 subjects were recruited (response rate, 97.0%), and their mean age (SD) was 35.4 (13.3) years. Overall, high plaque levels were observed in all untreated individuals. The prevalence of periodontitis and severe (stage III/IV) periodontitis using the American Academy of Periodontology and European Federation of Periodontology (AAP/EFP) classification were 85.4% and 48.5%, respectively. The prevalence of moderate-severe and severe periodontitis using the definitions of the Centers for Disease Control and Prevention (CDC) and AAP were 78.4% and 31.1%, respectively. The extent of periodontitis expressed as mean% of clinical attachment loss (CAL) ≥ 3 mm and CAL ≥ 5 mm were 34.9% and 14.4%, respectively, while the mean% of a periodontal probing depth (PPD) ≥4 mm and PPD ≥6 mm were 22.0% and 9.2%, respectively. Risk determinants associated with AAP/EFP periodontitis after the adjustment for other variables were age ≥35 years (odds ratio [OR] = 11.5) and lower income (OR = 2.5). Adjusted risk associations with stage II/IV periodontitis included age ≥35 years (OR = 8.2), males (OR = 2.5), lower income (OR = 2.3), and lower perceived stress (OR = 2.0). Adjusted risk associations with CDC/AAP moderate-severe periodontitis included age ≥35 years (OR = 12.0), lower income (OR = 2.1), and current cigarette smoking (OR = 4.2). Adjusted risk associations with CDC/AAP severe periodontitis included age ≥35 years (OR = 4.5), males (OR = 1.9), lower education (OR = 2.0), lower income (OR = 1.7), uncontrolled diabetes mellitus (OR = 2.0), and current cigarette smoking (OR = 2.3). CONCLUSIONS: The prevalence and extent of periodontitis were high in untreated subjects. Risk associations with untreated periodontitis included age ≥35 years, males, lower income, lower education, current cigarette smoking, uncontrolled diabetes mellitus, and lower perceived stress.


Assuntos
Diabetes Mellitus , Doenças Periodontais , Periodontite , Adulto , Humanos , Masculino , Doenças Periodontais/epidemiologia , Periodontite/epidemiologia , Prevalência
8.
Dent Mater J ; 41(1): 126-133, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34602588

RESUMO

This study aimed to evaluate the pulpal responses of monkey's pulp after direct pulp capping (DPC) with the novel mineral trioxide aggregate containing phosphorylated pullulan-based material (MTAPPL). Seventy-two teeth were randomly divided into four groups: MTAPPL; Nex-Cem MTA (NX); TheraCal LC (TH); and Dycal (DY). Histopathological changes in the pulps were observed at days 3, 7 and 70. On day 3, mild inflammatory responses were observed in the MTAPPL, no to moderate inflammatory responses in the TH, whereas moderate inflammatory responses in the NX and DY. No mineralized tissue formation (MTF) was observed in all groups. On day 7, no or mild inflammatory responses were observed in all groups. Initial MTF was observed except for DY. No inflammation with complete MTF including presence of odontoblast-like cells was observed in the MTAPPL, NX and TH groups at day 70. These findings indicate that MTAPPL could be an efficient DPC material.


Assuntos
Capeamento da Polpa Dentária , Agentes de Capeamento da Polpa Dentária e Pulpectomia , Compostos de Alumínio , Compostos de Cálcio , Hidróxido de Cálcio , Polpa Dentária , Combinação de Medicamentos , Glucanos , Óxidos , Silicatos
9.
J Adhes Dent ; 23(4): 357-365, 2021 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-34269546

RESUMO

PURPOSE: This study evaluated whether active application of self-etching adhesives would influence their microtensile bond strength (µTBS) to dentin cut with burs of different grit sizes. MATERIALS AND METHODS: Eighty-four human premolars were divided into 12 groups according to 1) two dentin surface preparations with either superfine- or regular-grit diamond burs; 2) three adhesives - Clearfil SE Bond 2 (SE2), Scotchbond Universal (SBU, 3M Oral Care) and G-Premio Bond (GPB, GC); and 3) two application modes of each adhesive (active or passive). Six bonded teeth per group were sectioned into sticks for µTBS testing. Statistical analyses were performed using 3-way ANOVA followed by Duncan's test (p < 0.05). Additional teeth were prepared to observe the interaction between the dentin smear layer obtained from each bur with adhesives under different application modes using transmission electron microscopy (TEM). RESULTS: Active application significantly increased the dentin bond strength of SE2, irrespective of the kind of bur used (p < 0.05). The highest bond strength of SBU was observed when bonded to superfine-grit diamond bur-cut dentin with the active application. There was, however, no influence of the tested factors on GPB group (p > 0.05). TEM observation showed that active application promoted dentin smear layer dissolution in all adhesive groups. CONCLUSIONS: Bond strengths of self-etching adhesives to dentin are influenced by bur-cut smear layers and mainly by application mode of adhesive materials. Active application improves µTBS of self-etching adhesives by enhancing smear layer modification and resin penetration into bur-cut dentin.


Assuntos
Colagem Dentária , Adesivos Dentinários , Adesivos , Resinas Compostas , Cimentos Dentários , Dentina , Humanos , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Resistência à Tração
10.
Dent Mater J ; 40(2): 538-546, 2021 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-33328395

RESUMO

This study evaluated the effects of remaining dentin thickness (RDT), different smear layers, and aging on the microtensile bond strength (µTBS) of universal adhesives to dentin when applied in self-etch mode. Ninety-six human third molars were randomly allocated to 12 groups (n=8) based on adhesives: ClearfilTM SE Bond 2 (SE, control), ClearfilTM Universal Bond (CU) and ScotchBondTM Universal Adhesive (SB); smear layers: prepared either with 600-grit SiC paper (P) or regular diamond bur (B); and aging: stored in distilled water at 37ºC for 24 hours (24h) or 1 year (1y). µTBS was significantly affected by the type of adhesives, smear layers, and aging (p<0.001). A statistically significant and positive linear relationship was also observed between µTBS and RDT (p<0.05) in all the tested groups, except for SEB1y and CUB24h (p>0.05). RDT, smear layer types, and aging can influence the bonding performances of universal adhesives when applied in self-etch mode.


Assuntos
Colagem Dentária , Camada de Esfregaço , Adesivos , Envelhecimento , Cimentos Dentários , Dentina , Adesivos Dentinários , Humanos , Teste de Materiais , Cimentos de Resina , Resistência à Tração
11.
Clin Exp Dent Res ; 6(6): 700-716, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32885613

RESUMO

PURPOSE: The purpose of this study is to systematically map all the factors that influence the fit and adaptation of zirconia crowns and/or copings. MATERIALS AND METHODS: The investigational strategy involved carrying out an electronic search between December 1, 2009 and September 1, 2019 through the Embase and Medline databases using Boolean operators to locate appropriate articles. RESULTS: A total of 637 articles were discovered after the removal of duplicates, and 46 of these were selected for evaluation. Further, a quality assessment was performed using GRADE evaluation criteria. CONCLUSIONS: Shoulder finish line preparations had slightly better marginal fit compared to chamfer finish lines. Crowns obtained from digital impressions had comparable to superior marginal adaptation compared to conventional impressions. Increasing cement space showed to improve zirconia crown adaptation. Cementation and veneering zirconia frameworks found to increase the marginal and internal gaps. Limited information is available on the effect of the alteration of sintering time/Temperature and/or sintering techniques on the adaptation of zirconia crowns. Most of the selected studies had a moderate quality assessment evaluation. Future studies could investigate the chair-side, ultra-fast sintering effect on the marginal gap of zirconia crowns.


Assuntos
Coroas , Preparo Prostodôntico do Dente/métodos , Zircônio/química , Desenho Assistido por Computador , Cimentos Dentários/química , Humanos , Propriedades de Superfície
12.
Eur J Oral Sci ; 128(3): 246-254, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32396258

RESUMO

Using transmission electron microscopy (TEM), this study investigated the characteristics of smear layers after preparation of dentin surfaces using different methods. In addition, this study analyzed, using scanning electron microscopy (SEM), the interactions of smear layers with the various acidic agents used subsequently to treat the dentin surface. Mid-coronal dentin surfaces were prepared according to one of five instrumentation methods: fracture; grinding with carbide bur; grinding with regular-grit diamond bur; grinding with superfine-grit diamond bur; or grinding with 600-grit silicon carbide (SiC) abrasive paper. Then, each prepared dentin surface was further divided into control (no further treatment) or treatment with one of the following agents: phosphoric acid solution (PAS); phosphoric acid gel (PAG); Clearfil SE Bond 2 Primer (SE2); or Scotchbond Universal Adhesive (SBU). Longitudinal ultra-thin sections were made for TEM observations. Dentin discs, representing each surface preparation and treatment method described above, were created, and the morphology was examined by SEM. The TEM results revealed differences in thickness and denseness of the smear layer, according to the different methods of instrumentation used to prepare the dentin surface. The two forms of phosphoric acid completely removed the smear layer in all groups. Agglomerated silica particles were observed on the top of the collagen layer after etching with PAG. For all dentin surfaces, except for that prepared with SiC, SE2 demonstrated better etching efficacy on different smear layers, whereas SBU provided only superficial interaction.


Assuntos
Colagem Dentária , Resinas Compostas , Cimentos Dentários , Dentina , Adesivos Dentinários , Humanos , Microscopia Eletrônica de Varredura , Cimentos de Resina , Camada de Esfregaço , Propriedades de Superfície , Resistência à Tração
13.
J Adhes Dent ; 22(3): 311-320, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32435771

RESUMO

PURPOSE: To evaluate the effects of double application of resin cement primers to dentin prepared with different diamond burs on the cement-dentin bond strengths. MATERIALS AND METHODS: Sixty flat dentin surfaces were prepared and divided into 12 groups (n = 5) according to three experimental factors: 1. resin cements: RelyX Ultimate (RU), Multilink Automix (ML), and Panavia V5 (PV); 2. resin cement primer application: single or double; 3. dentin surface preparation with regular or superfine diamond burs. Cement-dentin sticks (1 mm2) were prepared for and underwent microtensile bond strength testing (µTBS). Statistical analysis was performed using three-way ANOVA and Duncan's test (α = 0.05). Fractured surfaces and cement-dentin interfaces were observed using SEM. Additional teeth were used to observe the demineralization effect of resin cement primers with SEM and transmission electron microscopy (TEM). RESULTS: All tested factors demonstrated significant effects on µTBS (p < 0.001). The combination of PV with superfine-grit bur and double application yielded the highest bond strengths. Surfaces prepared with superfine-grit burs demonstrated higher µTBS than did the regular-grit group, but a significant effect was not observed for all groups. The double application of primer significantly increased the bond strength for most combinations, except for PV with superfine-grit bur-prepared dentin. CONCLUSIONS: PV showed higher bond strengths than other resin cements. Double application of primer improved the bond strength of all cements to dentin. Bond strengths were higher when dentin was prepared with a superfine-grit bur.


Assuntos
Colagem Dentária , Cimentos de Resina , Dentina , Adesivos Dentinários , Diamante , Teste de Materiais , Propriedades de Superfície , Resistência à Tração
14.
J Appl Oral Sci ; 27: e20180663, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31596368

RESUMO

OBJECTIVE: To investigate the use of polymethyl methacrylate (PMMA) electrospun fiber mats containing different amounts of polyethylene oxide (PEO) as a doxycycline delivery system and to test antibacterial activity against an oral pathogen. METHODOLOGY: PMMA powders or PEO (mol wt 200 Kd) (10,20,30% w/w/) were dissolved in N, N-dimethylformamide (DMF) to obtain a final polymer concentration of 15% in DMF (w/v). 2% Doxycycline monohydrate was added to the solutions and submitted to vortex mixing. The solution was transferred to a plastic syringe and fit into a nanofiber electrospinning unit. The parameters applied were: voltage at 17.2 kV; distance of 20 cm between the needle tip and the collector plate; target speed at 2 m/min; and transverse speed at 1cm/min. Syringe pump speed was 0.15 mm/min. The drug release analysis was performed by removing aliquots of the drug-containing solution (in PBS) at specific periods. Doxycycline release was quantified using RP-HPLC. Fiber mats from all groups had their antibacterial action tested against S. mutans based on inhibition halos formed around the specimens. The experiments were performed in triplicate. Gravimetric analysis at specific periods was performed to determine any polymer loss. Morphological characterization of the electrospun fibers was completed under an optical microscope followed by SEM analysis. RESULTS: The addition of PEO to the PMMA fibers did not affect the appearance and diameter of fibers. However, increasing the %PEO caused higher doxycycline release in the first 24 h. Fibers containing 30% PEO showed statistically significant higher release when compared with the other groups. Doxycycline released from the fibers containing 20% or 30% of PEO showed effective against S. mutans. CONCLUSION: The incorporation of PEO at 20% and 30% into PMMA fiber mat resulted in effective drug release systems, with detected antibacterial activity against S. mutans.


Assuntos
Antibacterianos/farmacocinética , Doxiciclina/farmacocinética , Nanofibras/química , Polietilenoglicóis/farmacocinética , Polimetil Metacrilato/farmacocinética , Análise de Variância , Antibacterianos/química , Cromatografia Líquida de Alta Pressão/métodos , Doxiciclina/química , Imersão , Microscopia Eletrônica de Varredura , Peso Molecular , Polietilenoglicóis/química , Polimetil Metacrilato/química , Reprodutibilidade dos Testes , Streptococcus mutans/efeitos dos fármacos , Fatores de Tempo , Água/química
15.
Dent Mater ; 35(11): e286-e297, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31551153

RESUMO

OBJECTIVE: To test the effects of addition of polyacrilonitrile (PAN) nanofibers and nanocrystal cellulose (NCC)-containing PAN nanofibers on flexural properties of experimental dental composites. METHODS: 11wt% PAN in dimethylformamide (DMF) solution was electrospun at 17.2kVA and 20cm from the collector drum. NCC was added to the solution at 3wt%. Fiber mats were produced in triplicates and tested as-spun. Strips (5cm×0.5cm) were cut from the mat in an orientation parallel and perpendicular to the rotational direction of the collector drum. Tensile tests were performed and ultimate tensile strength (UTS), elastic modulus (E) and elongation at maximum stress (%) were calculated from stress/strain plots. Fiber mats were then infiltrated by resin monomers (50/50 BisGMA/TEGDMA wt%), stacked in a mold (2×15×25) and light-cured. Beams (2×2×25mm) were cut from the slabs and tested in a universal testing machine. Data were analyzed by multiple t-test and one-way ANOVA (α=0.05). RESULTS: Addition of 3% NCC resulted in higher tensile properties of the fibers. Fibers presented anisotropic behavior with higher UTS and E when tested in perpendicular orientation. The incorporation of 3% NCC-PAN nanofibers resulted in significant increase in work of fracture and flexural strength of experimental dental composite beams. SIGNIFICANCE: NCC was found to be a suitable nanoparticle to reinforce experimental dental composites by incorporation via nanofiber. This fundamental study warrants future investigation in the use of electrospun nanofibres as a way to reinforce dental composites.


Assuntos
Nanofibras , Nanopartículas , Celulose , Resinas Compostas , Módulo de Elasticidade , Teste de Materiais , Resistência à Tração
16.
J Esthet Restor Dent ; 31(5): 423-430, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31140674

RESUMO

OBJECTIVE: As a result of advancements in chairside technology and speed sintering techniques and increased esthetic demands of patients, efforts have been made to produce monolithic zirconia restorations that are highly translucent, strong, and dense. While methods for processing zirconia are well known, there is a tendency to modify the process parameters with the aim of decreasing the overall processing time and, in particular, the sintering time. This review provides clinicians with scientific evidence of the effects of altering sintering parameters used for dental zirconia on its microstructure, phase transformation, and mechanical and optical properties. MATERIALS AND METHODS: A systematic search of Embase and Medline using Boolean operators was performed to locate relevant articles. RESULTS: Eleven articles were selected for this review. The following characteristics of monolithic zirconia have been confirmed to be affected by alterations in sintering: the microstructure, mechanical properties, optical properties, wear behavior, and low thermal degradation. CONCLUSIONS: The alteration of sintering parameters has been found to alter the grain size, wear behavior, and translucency of zirconia. There is a lack of clinical studies that investigate the influence of altering sintering parameters or methods on the clinical performance of monolithic zirconia restorations. CLINICAL SIGNIFICANCE: Alteration of sintering parameters alters the microstructural, mechanical, and optical properties of zirconia. This will consequently impact the clinical performance of zirconia prostheses. Future clinical investigations are encouraged to support these in vitro findings.


Assuntos
Cerâmica , Materiais Dentários , Humanos , Teste de Materiais , Propriedades de Superfície , Zircônio
17.
Dent Mater J ; 38(3): 361-367, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30814455

RESUMO

This study evaluated the effects of dehydration on the mechanical properties of adhesive resins and dentin, and on the microtensile bond strength (µTBS) of adhesives. Third molars were randomly bonded with Clearfil Mega Bond (MB) or Clearfil SE Bond 2 (SE). After water-storage (37°C; 24 h), µTBS was obtained in 'wet' (tested after 5 min of removal from storage) and 'dehydrated' (tested after 10, 15 min and 24 h) conditions by a universal tester (crosshead speed: 1 mm/min). Data were analyzed by two-way ANOVA and Duncan's test. Hardness (H), Elastic modulus (E) and weight-loss of dentin beams and adhesive-resin discs were also monitored over time and analyzed by one-way repeated measures ANOVA and Bonferroni's test (α=0.05). Significant differences in bond strength were observed for adhesives and for conditions. Except for dentin's E, dehydration caused significant gradual changes in the H, E and weight of adhesive resins and dentin (p<0.05).


Assuntos
Colagem Dentária , Adesivos Dentinários , Resinas Compostas , Desidratação , Cimentos Dentários , Dentina , Humanos , Teste de Materiais , Cimentos de Resina , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
18.
J Adhes Dent ; 21(1): 59-66, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30799472

RESUMO

PURPOSE: To evaluate the effects of double application of self-etch adhesives on their microtensile bond strength (µTBS) to dentin, as well as the hardness (H) of resin-dentin interfacial structures. MATERIALS AND METHODS: Midcoronal dentin surfaces (n = 45) were polished with 180-grit SiC paper and randomly allocated to 9 groups based on three adhesives - Scotchbond Universal Adhesive (SB), G Premio Bond (GP), and Clearfil Megabond 2 (MB) - and three application modes: single application (S), double application with light curing after each application (DL), and double application with light curing only at the end (D). Following composite-resin build up and water storage (37°C; 24 h), µTBS were obtained. The hardness of adhesive, resin-dentin interface and dentin were evaluated by nanoindentation. The µTBS and H data were analyzed by two-way ANOVA to demonstrate the effects of adhesive and application mode as well as their interaction, followed by Tukey's test (α = 0.05). Fracture modes were determined using a stereomicroscope. RESULTS: µTBS and H were significantly affected by the adhesives and their application modes (p ˂ 0.001). Double application significantly increased the µTBS and H of adhesive and resin-dentin interface (p ˂ 0.05). SB and MB showed significantly higher µTBS than GP (p ˂ 0.05). CONCLUSION: Double applications during bonding of dentin having clinically relevant smear layers were beneficial for three contemporary self-etch adhesives. The improvement in bonding performance is believed to be the result of increased chemical interaction, better solvent removal, and improved resin infiltration, leading to improved mechanical properties of the resin-dentin interface or thicker adhesive layers providing improved stress distribution.


Assuntos
Colagem Dentária , Camada de Esfregaço , Cimentos Dentários , Dentina , Adesivos Dentinários , Humanos , Teste de Materiais , Cimentos de Resina , Resistência à Tração
19.
J Prosthodont ; 28(3): 288-298, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30656786

RESUMO

PURPOSE: The marginal fit is an essential component for the clinical success of prosthodontic restorations. The aim of this study was to investigate the influence of different abutment finish line widths and crown thicknesses on the marginal fit of zirconia crowns fabricated using either standard or fast sintering protocols. MATERIALS AND METHODS: Six titanium abutments were fabricated for receiving zirconia molar crowns. Crowns were designed virtually and milled from partially sintered zirconia blanks and divided into 12 groups (n = 10/group). Crowns in groups 1 to 6 were sintered by standard sintering, while those in groups 7 to 12 were sintered by fast sintering. Groups were further categorized according to abutment finish line and crown thickness: G1/G7 (0.5 mm chamfer, 0.8 mm thick); G2/G8 (0.5 mm chamfer, 1.5 mm thick); G3/G9 (1.0 mm chamfer, 0.8 mm thick); G4/10 (1.0 mm chamfer, 1.5 mm thick); G5/G11 (1.2 mm chamfer, 0.8 mm thick); G6/G12 (1.2 mm chamfer, 1.5 mm thick). The marginal gaps were assessed at 8 locations using digital microscopy. The linear mixed effect model analysis was performed at a significance level of 0.05. RESULTS: All vertical marginal gaps were within the clinically acceptable range (∼11-52 µm). G8 (FS, 0.5 mm chamfer, 1.5 mm thick) demonstrated the largest gaps (47.95 µm, 95% CI: 44.57-51.23), whereas G3 (SS, 1.0 mm chamfer, 0.8 thick) had the smallest marginal gap (14.43 µm, 95% CI: 11.15-17.71). A linear mixed effect models showed significant differences for the interaction between finish line × crown thickness × sintering (F = 18.96, p < 0.001). The lingual surfaces showed the largest gaps in both sintering protocols, while the mesial and mesiobuccal surfaces demonstrated the smallest gaps. CONCLUSIONS: There was a significant interaction between finish line widths, crown thickness, and sintering protocol on the marginal gaps in both sintering protocols; 1.0 mm finish line preparations with either 0.8 mm or 1.5 mm occlusal reduction had better marginal fit in both sintering protocols compared to 0.5 mm or 1.2 mm finish lines. Smaller marginal discrepancies were observed for standard sintering crowns with a 0.5 mm finish line and 1.5 mm occlusal reduction. Conservative occlusal reduction should be accompanied with a 1.2 mm finish line to obtain better marginal fit for full-contoured zirconia crowns.


Assuntos
Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Desenho Assistido por Computador , Coroas , Zircônio
20.
Clin Oral Investig ; 23(6): 2629-2635, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30327950

RESUMO

OBJECTIVES: To evaluate the effects of air-blowing time and storage time on microtensile bond strength (µTBS) of universal adhesives to dentin. MATERIALS AND METHODS: Ninety flat dentin surfaces from extracted human third molars were bonded with three universal adhesives (Clearfil Universal Bond-CU; G-Premio Bond-GP; Scotchbond Universal Adhesives-SB). Bonded dentin surfaces were air-dried for 5 s, 15 s, or 30 s followed by resin composite built-up. Resin-dentin beams were tested with µTBS test after different storage time in distilled water (24 h and 1 year). Data were analyzed by three-way ANOVA and Duncan test at (α = 0.05). Failure mode and resin-dentin interfaces were observed using a scanning electron microscope (SEM). Specific features of fractured beams after µTBS were further observed using SEM at high magnification. RESULTS: Extension of air-blowing time from 5 s to 30 s increased the 24 h µTBS of CU only. Bond strength of all adhesives significantly decreased after 1-year storage except for CU at 5 s and 30 s of air-blowing time. One-year µTBS were significantly higher when air-blowing times were extended to 15 s for SB and 30 s for CU. Air-blowing time had no influence on GP. CONCLUSION: The effect of air-blowing time and storage time on resin-dentin bond was material-dependent. CLINICAL RELEVANCE: Extended air-blowing time increased the bond strength and bond durability of CU. Extension of air-blowing time to 15 s and 30 s improve the long-term bond strength of SB and CU, respectively.


Assuntos
Ar , Resinas Compostas , Colagem Dentária , Adesivos Dentinários , Dentina , Cimentos Dentários , Humanos , Teste de Materiais , Dente Molar , Cimentos de Resina , Resistência à Tração , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...